(509) 352-0550

Grease Trap Rules in Coeur d’Alene, Idaho: The 25% Rule Without a Calendar

Across the state line it is Idaho law and Kootenai County. Coeur d’Alene’s sewer code says an interceptor is no longer maintained once grease and solids take more than 25% of it, and sets no interval at all.

Call (509) 352-0550

A different state, a different code

Nothing on our Spokane County pages applies in Coeur d’Alene. The city is in Idaho, runs its own treatment plant, and has had a Pretreatment Program since 1984. “All non-domestic users shall comply with City Code 13.20, the City’s Sewer Use Ordinance” (Pretreatment Program page); homes and apartment buildings are domestic dischargers outside the program, a restaurant is not. The chapter is administered by the superintendent, “the person designated by the city to supervise the operation of the POTW” (13.20.1.3), who will “administer, implement, and enforce the provisions of this chapter” (13.20.1.2).

Contact. City of Coeur d’Alene Wastewater Department, 710 E. Mullan Ave, Coeur d’Alene, ID 83814. Pretreatment Office (208) 769-2276; city main line 208-769-2300; after-hours sewer emergency 208-769-2241.

What the code requires

The grease-interceptor rule is 13.20.2.10.C: “Grease, oil, and sand interceptors must be provided when, in the opinion of the superintendent, they are necessary for the proper handling of wastewater containing excessive amounts of grease and oil, or sand; except that such interceptors will not be required for residential users. All interception units must be of type and capacity approved by the superintendent and must be located to be easily accessible for cleaning and inspection. Such interceptors must be inspected, cleaned, and repaired regularly, as needed, by the user at his expense.”

Then the line that does the work, 13.20.2.10.C.1: “A grease interceptor or a grease trap is not considered to be properly maintained if for any reason it is not in good working condition with all internal required plumbing of proper design and length in place, or if the operational fluid capacity has been reduced by more than twenty five percent (25%) by the accumulation of floating and settled solids, oils, and greases. The owner of any premises required to install a grease interceptor, the lessee and sublessee, if any, and any proprietor, operator, or superintendent of such facility are individually and severally liable for any failure of proper maintenance of such grease interceptor.” And: “If the grease interceptor is not maintained adequately under the conditions of use, the grease interceptor must be resized and the user must install one which is effective in accomplishing the intended purpose.”

So: a 25% rule, no calendar, and liability that reaches the tenant and the manager as well as the building owner. There is no 30-day or 90-day clock here; “regularly, as needed” means the reading decides.

How a cleaning must be done

The same section specifies the method. “When a grease interceptor/trap is cleaned, the sidewalls must be scraped and hosed down, while all the solids and liquids contained are removed. All wastes removed from any grease interceptor/trap must be legally disposed of other than to the sewer.” The city “specifically prohibits” three practices: “a. Pumping to remove only accumulated sediments or floating materials; b. Pumping operations which specifically separate floating or sediment interceptor solid wastes from wastewater and then return or decant the separated wastewater back into the grease interceptor/trap; c. Transporting any hauled pollutants from another location for discharge into a grease interceptor/trap.” And: “Use of grease trap/interceptor treatment products, including bacteria, designed to digest the grease, is specifically prohibited.”

The discharge limits behind it

The prohibited-discharge list (13.20.2.1.B) bans FOG “that causes or contributes to pass through, interference or otherwise causes the City to clean the collection system more frequently” (item 26), grease that will “solidify or become discernibly viscous” between 32°F and 150°F (27), and “animal fat or grease by-product in excess of one hundred fifty milligrams per liter (150 mg/l),” a limit that “will not apply if the industrial user has installed and is properly operating and maintaining a gravity grease interceptor and implementing all required BMPs” (28). Item 29 bans pumping interceptor waste back to the sewer without city approval. Sizing is “type and capacity approved by the superintendent,” and pretreatment plans “must be submitted to the city for review and approval before construction” (13.20.2.8).

Records

Section 13.20.4.10 requires “users subject to the reporting requirements of this chapter” to keep monitoring and BMP records for “at least five (5) years.” It is written for permitted and reporting users, not as a pump-log rule for every restaurant, and chapter 13.20 has no separate grease-log section. We give every Coeur d’Alene kitchen a dated record with the percent-full reading and the disposal manifest regardless; it is the only way to show an inspector the 25% line was respected.

Enforcement

A violation brings “a written notice of violation via certified letter,” with a correction plan due from you “within fifteen (15) days” (13.20.9.1). If a compliance order is not met, “sewer service may be discontinued” (13.20.9.4). Administrative fines run up to “one thousand dollars ($1,000.00) [...] on a per violation, per day basis,” with a 10% late penalty, 10% monthly interest and a lien on the property if unpaid (13.20.9.6); civil penalties are “one thousand dollars ($1,000.00) per violation, per day,” plus fees, costs and damages (13.20.10.2); a wilful or negligent violation is a misdemeanor (13.20.10.3).

What we do not quote

Any Wastewater Department FOG handout, the “required BMPs” list that item 28 refers to, sizing guidance outside the code, and the SIU/CIU Wastewater Service Application. The Pretreatment Office at (208) 769-2276 has all of them. Post Falls, Hayden and unincorporated Kootenai County have their own rules, which this page does not cover.

How we service Coeur d’Alene kitchens

There is no calendar to keep, so the reading sets the interval. We measure the floating and settled layer before every pump-out, write the percentage on the record, and plan the next visit at 20% so the tank is never past 25% between services. The cleaning is the one the code describes: all solids and liquids out, sidewalls scraped and hosed, nothing decanted back, no additives, and a manifest showing the waste was “legally disposed of other than to the sewer.” Same truck that runs Spokane; Sherman Avenue, Northwest Boulevard and Riverstone are a short drive over the line. If your interceptor keeps hitting 25% faster than the schedule, the code’s answer is resizing, and we will say so rather than sell you more visits.

Coeur d’Alene, on the 25% rule

Device size and address. The reading sets the interval; the record proves it.

Call (509) 352-0550
Plain-English guidance, not legal advice. Quotations are from the Municipal Code of Coeur d’Alene, Idaho, Chapter 13.20 “Uniform Wastewater Requirements,” American Legal Publishing version 2026 S-16 (current), and from the city’s Pretreatment Program page, both read 2026-10-23. Coeur d’Alene is in Kootenai County, Idaho; Spokane County Code does not apply there. Confirm current requirements with the Pretreatment Office at (208) 769-2276.
📞 Tap to call (509) 352-0550