Who administers it
The City of Airway Heights Public Works Department, through its Wastewater Pretreatment Program. “Director” in the code “means the Public Works Director for the City of Airway Heights, or his/her designee” (AHMC 13.06.200). The city is not a Spokane County sewer customer: it runs its own Water Reclamation Plant, operates pretreatment under an interlocal agreement with the City of Spokane (13.06A.0106), and “adopts by reference Chapter 13.03A of the City of Spokane Municipal Code as the wastewater pretreatment control regulations for the City of Airway Heights, as now in effect and as subsequently amended” (13.06A.010). The grease-interceptor maintenance rule, though, is Airway Heights’ own, in chapter 13.06.
The program page says it plainly: “Business owners and managers are responsible for maintaining grease interceptors, and documenting the cleaning schedule. Documentation must be available at the time of inspections by the Wastewater Pretreatment Program staff. Cleaning can be done by a contractor or by the business.”
Contact. The program page prints (509) 241-3204 for the Wastewater Pretreatment Program. The phone link behind that number carries a different number, so if 241-3204 does not reach the program, the city’s main line is (509) 244-5578. The page also gives a program e-mail address, which we do not reproduce here.
Who must have an interceptor
“Any commercial food facility which generates grease waste shall include a grease interceptor as part of their sewer, or where required by the Director, the division of building and planning, or the Health Officer, including but not limited to hotels, boardinghouses, restaurants, or food processing facilities” (13.06.1340). Sizing comes from the Sewer Standards Handbook, the city’s Public Works Standards Manual (13.06.600), which says a grease trap “shall comply with the provisions of Section 7 of the most current Uniform Plumbing Code, and shall result in the discharge of no more than 100 mg grease per liter” (§ 5A.011; the chapter is dated 2000), and the program page says the building inspector “will refer to the Uniform Plumbing Code” to check the size. The local limits are 100 mg/L oil and grease (HEM) and 50 mg/L non-polar (SGT-HEM) (13.06A.0204).
The maintenance rule
AHMC 13.06.1370, Grease interceptors, oil/water separators, sand traps – Maintenance, is the section that sets the interval, the records and the cost recovery. The operative sentences: “Where installed, all grease interceptors, oil/water separators, and sand traps shall be maintained by the owner, at his/her expense and liability, in good order and condition at all times. [...] All grease interceptors shall be inspected every six months and pumped as needed by a licensed septic tank pumper; there shall be a minimum of one pumping per year. Upon request from the Director, the owner shall provide receipts of inspections and/or pumping. The owner shall keep all receipts for a one-year period. If proper inspection and/or maintenance is not provided, the Director may order the same performed, and all costs incurred, including any related clean-up of the public sewer shall be billed as an additional utility service to the premises concerned. Expenses charged shall include, but are not limited to, pumping, inspection, correcting the problem and cleaning the public sewer” (Ord. C-381, 1997).
- Inspect every six months.
- Pump as needed, and at least once a year regardless.
- By a licensed septic tank pumper.
- Keep receipts of inspections and pumping for one year; produce them when the Director asks.
Chapter 13.06 sets no 25% line. One caution we owe you: because 13.06A adopts Spokane’s SMC 13.03A “as now in effect and as subsequently amended,” any grease-control cleaning rule inside that Spokane chapter may also bind an Airway Heights kitchen alongside 13.06.1370. We do not quote SMC 13.03A on this site; the Pretreatment Program is the office that can tell you whether a shorter interval applies to you.
Inspection, enforcement and cost recovery
The Director “shall have free access at proper hours to all buildings and premises served by the sewerage system” (13.06.040). A violation draws a notice “to correct the violation within 30 days” (13.06.1470.C); the civil penalty is “not to exceed $1,000,” with “each day of a continuing violation” a separate violation (13.06.1600.A–B). The program page restates the cost recovery: “If the City has to clean a sewer main blocked by FOG originating from a commercial establishment, the commercial establishment shall reimburse the City for those costs, in accordance with AWHMC 13.06.”
What we do not quote
The current eCode360 text of chapters 13.06 and 13.06A — the version quoted here is dated January 2025, and the city has passed ordinances since; the Standards Manual’s Appendix D “Grease Interceptor Checklist”; the fee resolution (13.06A.1401 says permit, inspection and renewal fees are set “through resolution,” not in the code); and Spokane’s SMC 13.03A. For any of those, the Wastewater Pretreatment Program at (509) 241-3204 is the office to ask.
How we service Airway Heights kitchens
Two visits a year at minimum, written up as the code describes them. Every six months we open the interceptor, measure the grease and solids, and leave a dated inspection record; if the reading says pump, we pump that day, and whatever the readings say, the device is pumped at least once in every twelve months. The pump-out is full — pumped dry, baffles and tees washed, wash water hauled off — with a manifest for where the waste went. Ask any pumper, us included, for the license before the lid comes off; 13.06.1370 requires one. We plan at 20% so a busy kitchen on Highway 2 is never over the line between inspections, and we keep our own copy of every receipt past the one year the code asks of you.
Airway Heights: six-month inspections, receipts in hand
Device size and address. We write the inspection record the Director asks for.